 "basis":"Sensitivity envelope and synthetic instrument exercise anchored to the executed 2D FEA cases; no physical stiffness or fatigue rating.",
 "seed":50050,"samples_per_load_position":10000,
 "profile":"window_12mm","load_range_N":[450,550],"E_range_GPa":[66,72],"thickness_range_mm":[19.9,20.1],"support_range_MN_m":[16,24],
 "out_of_plane_offsets_mm":[0,2,5],"rotational_support_Nm_rad":[100,500,2000],
 "synthetic_sensor_noise_mm":0.0005,"synthetic_hysteresis_halfwidth_mm":0.001,
 "load_cycle_N":[0,100,200,300,400,500,400,300,200,100,0],"cycles":3,
 "nominal_yield_MPa":240,"elastic_screen_factor":2,"stress_concentration_screens":[1,2,3]
}